Configuration Parameter  | 
Selectable Option/Value  | 
Description  | 
Timer group  | 
0--1  | 
Select timer group  | 
Module  | 
0--1  | 
Select timer module  | 
Timer pre-scaler  | 
2--4--8--16--32--64--128  | 
How quickly the timer’s counter is “ticking”. This set the divider, that will be used as a divisor of the incoming 80 MHz APB_CLK clock.  | 
Alarm mode  | 
TIMER_AUTO_RELOAD_EN--TIMER_AUTO_RELOAD_DIS  | 
Enable or disable auto-reload of the alarm.  | 
Interrupt interval (sec)  | 
  | 
Select the interrupt interval in seconds  | 
Port Name  | 
Date Type  | 
Description  | 
ISR  | 
Function-Call  | 
ISR port will output a logic ‘true’ signal that could activate a function-call subsystem in Simulink.  | 
This block can be used to set up an Interrupt Service Routine (ISR) that could be triggered by a built-in timer module in the ESP32.
The ESP32 chip contains two hardware timer groups. Each group has two general-purpose hardware timer(s). They are all 64-bit generic timers based on 16-bit pre-scalers and 64-bit up / down counters which are capable of being auto-reloaded. By default, the timer counter is set to 0 and is counted upwards. The alarm is also enabled by default while giving the user the ability to enable or disable auto-reload of the alarm.
Demo file : esp32_timer_interrupt_demo.slx

This example shows how to use the Timer interrupt block. In this model an interrupt service routine (ISR) is called at a 0.5-second interval. Within the ISR, a GPIO pin is toggled to indicate the interrupt call.
An oscilloscope should be connected to the GPIO pin specified in the model (in the example GPIO Pin 2 is selected.)
After the model file is compiled and uploaded to the ESP32 board, the following output can be seen on the oscilloscope.