Please enable JavaScript to view this site.

Waijung 2 User Guide

Navigation: Zynq-7000 target > Block references > Additional features

Processor in the loop (PIL) simulation

Scroll Prev Top Next More

Introduction

The Waijung 2, ZYNQ7000 embedded target allows the user for Code Verification and Validation in ZYNQ7000 using Processor-In-the-Loop(PIL) Simulation. Using this simulation mode, you can test whether your model and generated code are numerically equivalent. Simulink PIL supports three different simulation modes. For more information go to Code Verification and Validation with PIL.

Features

The PIL  implementation support the following features,

PIL simulation supports code execution profiling

Supported OS:

Bareboard

FreeRTOS

Supported communication interfaces:

Serial

TCP/IP

Limitations

When the PIL communication interface is serial, specified UART driver module blocks cannot be used in the model for other tasks.

When the PIL communication interface is TCP/IP, Ethernet driver blocks cannot be used in the model for other tasks. Additionally, when using this communication interface in BareBoard OS, Timer Interrupt driver cannot be used as well.

These conditions are automatically checked during the build process and an error is thrown to stop the build process.

The minimum sample time that PIL can simulate depends on the

OS

The drivers that you are going to test

PIL simulation in Waijung 2  ZYNQ7000 target only supports Model block simulation mode.

Configuration Parameters

PIL host-target communication can be configured in the target setup block mask.

zynq_7000_processor_in_the_loop_host_setup_block_1

Configuration Parameter

Selectable Option/Value

Default Value

Description

Communication Interface

Serial

TCP/IP

Serial

Select the communication interface external mode uses to exchange data between the host and the target hardware.

DEVICE ID

 

XPAR_PS7_UART_0_DEVICE_ID

XPAR_PS7_UART_1_DEVICE_ID

or

 

XPAR_PS7_ETHERNET_0_DEVICE_ID

XPAR_PS7_ETHERNET_1_DEVICE_ID

XPAR_PS7_UART_0_DEVICE_ID

or

XPAR_PS7_ETHERNET_0_DEVICE_ID

 

 

Select the device ID of the driver module depends on the Communication interface as well as the Hardware reference design file (.xsa).

 

 

Serial Port: COM

 

20

Enter the ‘COM’ part to which the target is connected.

Baud Rate

9600

115200

115200

Select the baud rate for serial communication.

IP Address

 

192.168.1.10

Enter the IP address

Netmask

 

255.255.255.0

Enter the netmask IP address

Gateway

 

192.168.1.1

Enter the gateway IP address

Port

 

256

Enter the network port

MAC address

 

00-0a-35-00-01-02

Enter the MAC address

Setting Up Simulink Model(s) for PIL Simulation

Two Simulink models are required for the PIL simulation using Model block Simulation mode; Reference model and Top model.

Reference model

This model is used to contain all the blocks which are related to the task(algorithm) that should be run on the target. Add the required input and outputs using input ports and output ports

Top model

Top model can be used to send the input signals to the reference model and monitor the output signals from the reference model. In addition to that, this model is used to simulate algorithms on the host and can be compared with the reference model outputs(Note: driver specific blocks cannot be simulated on the host).

 

Note: Model block is used on the top model to link the reference model with the top model.

 

The following steps are required to set up any simulink model for PIL simulation

In the Reference model,

 

1.Add the Waijung2 Target Setup Block and browse the xsa file in the ZYNQ7000 tab.

2.Set the Build options to Processor-in-the-loop simulation in the  Waijung2 tab and click Apply. Host-board connection tab would appear on the block mask.

zynq_7000_processor_in_the_loop_host_setup_block_2

3.From the Host-board connection tab, select the preferred communication interface i.e. serial, tcp/ip and fill in the necessary configurations for the selected interface.

4.Implement the algorithm for the target and add the required input and output ports and save the model

 

In the Top model,

1.Add the PIL Host Setup block

This block is only used to set required Model Configuration parameters in the Top model.

zynq_7000_processor_in_the_loop_host_setup_block_3

2.Add a Model block to link the Reference model. In the Model block mask,

a.Browse the reference model file

b.Change the Simulation mode to Processor-in-the-loop

c.Change the Code interface to Model reference

zynq_7000_processor_in_the_loop_host_setup_block_4

3.Connect the input and output port of the model block to required inputs(e.g: pulse generators, constant blocks,... ) and outputs(e.g: scope,....).

4.To enable the SIL/PIL toolstrip on Simulink go to Apps → SIL/PIL Manage

5.Then go to SIL/PIL tab

a.Change the Mode to Automated Verification

b.Change the System Under Test to Model blocks in SIL/PIL mode

c.Change the Top Model Mode to  Normal

d.Set the Stop Time to finite value

zynq_7000_processor_in_the_loop_host_setup_block_5

6.Save the model file and click on the Run Verification button on the SIL/PIL tab to build, compile and run the simulation.

7.Once the simulation is finished, open the scope or output source to see the simulation data.

8.If you need to see the code execution profiling report, in the Top model go to SIL/PIL tab → Compare Runs → Generate Report.  It will generate a report about the execution profiling

Example

1.Reference model

Demo file location: [ waijung2 installation folder ]\targets\zynq7000\demo\pil_demo\pil_demo_ref.slx

zynq_7000_processor_in_the_loop_host_setup_block_6

2.Top model

Demo file location: [ waijung2 installation folder]\targets\zynq7000\demo\pil_demo\pil_demo_top.slx]

zynq_7000_processor_in_the_loop_host_setup_block_7

Description

This is a simple example to showcase the capabilities of using the PIL feature. In this model, GPIO Out block is used to generate the signal from MIO0 pin which is input from the Top model(pil_demo_top.slx) and the GPIO Input block is used to read the MIO9 and output that signal to the Top model. And in addition to that, the input signal is directly sent to the Top model.

 

The demo file is configured to use serial as the communication interface for PIL simulation.

 

Note: Before running the simulation, change the COM port from the Waijung2 Target Setup Block mask and short circuit the MIO0 and MIO9 pins(in JF Connector in zybo z7 board).

 

When the simulation starts running, double-click to open the Scope. This simulation runs for 10 seconds.

What should be happening?

The scope plots the simulated input signals and the digital input output readings from the target hardware.

zynq_7000_processor_in_the_loop_host_setup_block_8

The code execution profiling report can be generated by going to SIL/PIL tab → Compare Runs → Generate Report in the Top model.

 

Copyright 2024 Aimagin Co.,Ltd. Rev.1454